My watch list
my.chemeurope.com  
Login  

DESY light source PETRA III now has the world's sharpest X-ray eyes

Scanning X-ray microscope reaches record resolution of 10 nanometres

Schroer et al.

X-ray micrograph of a test pattern made of tantalum measured at PETRA III beamline P06.

30-07-2012: A novel X-ray microscope at DESY offers the world's sharpest X-ray vision: Thanks to the extraordinary brilliance of DESY's X-ray source PETRA III, this microscope is able to resolve details as small as ten nanometres – which is about ten thousand times thinner than a human hair. Only few facilities worldwide are able to reach a comparable optical resolution.

The instrument was jointly developed by a team led by Professor Christian Schroer from the Technical University of Dresden and DESY researchers at the experiment station P06 and partly funded  by the German Federal Ministry of Research. It is already available to users, and possible applications include, for example, imaging the structure of microchips, investigating carbon nanotubes and studying the chemistry of catalyst nanoparticles.

The scanning X-ray microscope employs a technique known as ptychography. Instead of directly imaging the probe, ptychography combines many diffraction patterns generated when a fine X-ray beam scans the probe. "This way ptychography can overcome the limitations of conventional microscopy regarding the spatial resolution", explains Schroer.

The more details on the fringes of the individual diffraction patterns can be recorded, the higher the resulting resolution. Thanks to the extreme brightness of PETRA III the diffraction patterns are exceptionally detailed, resulting in a spatial resolution of ten nanometres, which is at least twice as good as in conventional microscopy.

"This is a prime example for the use of a high brilliance source", underlines Schroer. His group demonstrated the capabilities of the new scanning X-ray microscope by imaging a Siemensstern, a star-like pattern with alternating white and black rays, made of the metal tantalum. The technique is suited for a wide range of applications in the nano cosmos as well as in geo-  and environmental sciences, and biomedicine.

As the resolution of the microscope is in principle only limited by the X-ray density on the sample, an even sharper X-ray vision may become  possible in the future. By optimising the focussing X-ray optics a resolution of at least one nanometre should be achievable.

Original publication:
"Hard x-ray scanning microscopy with coherent radiation: Beyond the resolution of conventional x-ray microscopes", A. Schropp et al., Appl. Phys. Lett. 100, 253112 (2012)

Watchlist

This is where you can add this news to your personal favourites

Additional Information

Facts, background information, dossiers
More about Deutsches Elektronen-Synchroton DESY
Contact
Deutsches Elektronen-Synchroton DESY
Notkestrasse 85
22607 Hamburg
Germany
Phone
+4940-8998-0
  • News

    Liquid on liquid goes solid

    Not all liquids are mixable. Researchers from the Institute of Experimental and Applied Physics of Kiel University (CAU) have investigated chemical processes with atomic resolution at the interface between two such liquids and have made an exciting discovery. During an experiment carried ou ... more

    DESY light source PETRA III now has the world's sharpest X-ray eyes

    A novel X-ray microscope at DESY offers the world's sharpest X-ray vision: Thanks to the extraordinary brilliance of DESY's X-ray source PETRA III, this microscope is able to resolve details as small as ten nanometres – which is about ten thousand times thinner than a human hair. Only few f ... more

    Scientists measure soot particles in flight

    For the first time, air-polluting soot particles have been imaged in flight down to nanometre resolution. Pioneering a new technique, the international team, including researchers from DESY, snapped the most detailed images yet of airborne aerosols. “For the first time we can actually see t ... more

More about TU Dresden
Contact
Technische Universität Dresden
Universitätsgelände
01062 Dresden
Germany
Phone
+49351463-0
Fax
+49351463-37168
  • News

    DESY light source PETRA III now has the world's sharpest X-ray eyes

    A novel X-ray microscope at DESY offers the world's sharpest X-ray vision: Thanks to the extraordinary brilliance of DESY's X-ray source PETRA III, this microscope is able to resolve details as small as ten nanometres – which is about ten thousand times thinner than a human hair. Only few f ... more

    „UMSICHT“ science award goes to a Dresden scientist for Organic Solar Cells

    On 4th July 2012 the UMSICHT scientific award 2012 was awarded to the scientist Jan Meiß for his dissertation „New Material Concepts for Organic Solar Cells“. The award was presented to him in Oberhausen by Prof. Dr. med. Dietrich Grönemeyer, Chairman of the Wissenschaftsforum Ruhr e.V., wh ... more

    Ferromagnetism plus Superconductivity

    It actually seems impossible:  Scientists from the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) and theTU Dresdenwere able to verify with an intermetallic compound of bismuth and nickel that certain materials actually exhibit the two contrary properties of superconductivity and ferromagnetis ... more

  • Job Offers

    Chair (W3) of Molecular Functional Materials (f/m)

    Chair (W3) of Molecular Functional Materials The position as Strategic Professorship within the Cluster of Excellence ‘Center for Advancing Electronics Dresden’ (cfaed) is to be filled at the earliest possible date. cfaed is a cluster of excellence within the German Excellence Initiative. ... more

Your browser is not current. Microsoft Internet Explorer 6.0 does not support some functions on Chemie.DE