10-Oct-2008 - National Physical Laboratory (NPL)

Scientists design bomb-proof thermometer to measure the heat of explosions

The thermometer can take 50,000 measurements per second up to 3000 K (2727 °C).

Scientists at the UK's National Physical Laboratory (NPL) in Teddington have designed a high-speed thermometer that can measure the temperature inside explosions without being damaged in the impact.

The shockwave, heat, soot and debris from an explosion can damage thermometers. Conventional thermocouples do not react quickly enough to capture the information. This makes modeling the interaction of an explosion with its environment problematic – as temperature is essential in any calculations.

NPL scientists have now designed a reusable bomb-proof thermometer to understand the physical and chemical processes that occur during the detonation and expansion phases of an explosion. It is an optical fibre 400 microns (0.4 mm) across, protected from the blast by a sand-packed steel tube with one open end.

The thermometer detects thermal radiation at four different wavelengths, collecting more information about the thermal physics of the explosion than could be obtained from any one wavelength alone. The optical fibre probe collects thermal radiation, which is transmitted over a suitable safe distance to the main instrumentation.

To measure the temperature of the fireball, the thermometer was first calibrated up to 3000 K (2727 °C). This made it possible to convert the measured thermal radiation signals into temperatures. The thermometer can take 50,000 measurements per second, producing a detailed profile of temperature changes during a split-second detonation.

After a successful simple field trial NPL now hopes to examine much larger explosions. The findings will help to fine tune predictive models on many different explosion parameters.

NPL lead scientist, Gavin Sutton said: "We produced a working prototype thermometer after some successful field trials and hope to measure the temperature of full-scale explosions in the near future. The lab tests involved temperatures of over 3000 kelvin and the only damage done was a small amount soot off the end of the optic fibre – which we easily removed with alcohol and a cotton bud."

Facts, background information, dossiers
More about National Physical Laboratory
  • News

    New test detects drug use from a single fingerprint

    Led by the University of Surrey, a team of researchers from the Netherlands Forensic Institute (NL), the National Physical Laboratory (UK), King’s College London (UK) and Sheffield Hallam University (UK), used different types of an analytical chemistry technique known as mass spectrometry t ... more

    On the edge of graphene

    Researchers at the National Physical Laboratory (NPL) have discovered that the conductivity at the edges of graphene devices is different to that of the central material. Local scanning electrical techniques were used to examine the local nanoscale electronic properties of epitaxial graphen ... more

    Quantum model helps solve mysteries of water

    A research team from the National Physical Laboratory (NPL), the University of Edinburgh and IBM's TJ Watson Research Center has revealed a major breakthrough in the modelling of water that could shed light on its mysterious properties. Water is one of the most common and extensively studie ... more

  • Videos

    The Watt balance and redefining the kilogram

    Video by the National Physical Laboratory (NPL) with Dr Bryan Kibble, Dr Tony Hartland and Dr Ian Robinson more